<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Liquid Effluent Monitors | Radiation Monitoring</title>
	<atom:link href="https://www.sciwise.ca/product-category/liquid-effluent-monitors/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.sciwise.ca/product-category/liquid-effluent-monitors/</link>
	<description></description>
	<lastBuildDate>Wed, 01 May 2024 11:50:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5.7</generator>

<image>
	<url>https://www.sciwise.ca/wp-content/uploads/2021/08/cropped-logo-new-32x32.png</url>
	<title>Liquid Effluent Monitors | Radiation Monitoring</title>
	<link>https://www.sciwise.ca/product-category/liquid-effluent-monitors/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Wdms monitoring and disposal system for radioactive waste waters</title>
		<link>https://www.sciwise.ca/product/wdms-nt-vk/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 30 Jul 2021 10:50:26 +0000</pubDate>
				<guid isPermaLink="false">https://dev3085.marketing-aide.com/?post_type=product&#038;p=3838</guid>

					<description><![CDATA[<p>MONITORING AND DISPOSAL SYSTEM FOR RADIOACTIVE WASTEWATERS</p>
<p>The WDMS NT-VK system is designed to collect and monitor radioactive wastewaters, which can be released only after their radioactivity drops below a defined value.</p>
<p>NT: Number of Tanks, indicates how many decay tanks are used in the system</p>
<p>VK: Volume in Kiloliters, indicates the volume of each decay tank expressed in kiloliters</p>
<p>The post <a href="https://www.sciwise.ca/product/wdms-nt-vk/">Wdms monitoring and disposal system for radioactive waste waters</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>The WDMS NT-VK main components are the following:</p>
<ul>
<li>Purification group: Imhoff tanks designed to collect the wastewaters coming from the wards and to separate liquid from solid waste</li>
<li>Sorting group: pumps and conduits system designed to pour the wastewaters in the decay tanks</li>
<li>Decay group: decay tanks array to hold and stock the wastewaters until their radioactive level drops below a defined value</li>
<li>Sampling system: valves and pumps to perform the washing of the sampling circuit and the sampling of the stocked wastewaters, allowing the measurement in Marinelli geometry</li>
<li>Release group: depending on the monitoring results, the wastewaters contained in the sampled tank can be released in the sewers</li>
<li>Safety groups and devices: they mainly consist in guard levels – installed in all the system critical stages – which stop the wastewaters flow in case of detected anomaly, and a safety flooding well which can collect and stock wastewaters potentially overflowing from any system group</li>
</ul>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>The entire system is locally managed by a PLC, which is commanded by a remote management software installed on a PC.</p>
<p>Through the interactive synoptic interface of the software the operator can activate the system automatic cycles, set the measurement parameters, visualize the alarms and release archives, and monitor the system’s status (filling levels, pump stages, measurements, alarms). Depending on the measurement results, and as defined by the procedures in force, the operator can also activate the monitored wastewaters release in the sewers.</p>

		</div>
	</div>
</div></div></div></div>
<p>The post <a href="https://www.sciwise.ca/product/wdms-nt-vk/">Wdms monitoring and disposal system for radioactive waste waters</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lem- Liquid Effluent Monitoring System</title>
		<link>https://www.sciwise.ca/product/lem/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 30 Jul 2021 10:39:28 +0000</pubDate>
				<guid isPermaLink="false">https://dev3085.marketing-aide.com/?post_type=product&#038;p=3833</guid>

					<description><![CDATA[<p>LIQUID EFFLUENT MONITORING SYSTEM</p>
<p>The LEM system allows to sample the liquid effluents and to perform a gross gamma measurement of the specific activity in Marinelli geometry.</p>
<p>The post <a href="https://www.sciwise.ca/product/lem/">Lem- Liquid Effluent Monitoring System</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>LEM system is composed of the following main parts:</p>
<ul>
<li>Stainless steel support structure</li>
<li>Electrical and command board with panel PC integrated in the stand</li>
<li>Measurement system: NaI(Tl) detector, electronics for HV and signal processing, 1 l Marinelli, 5 cm lead shielding well</li>
<li>Self-priming pump</li>
<li>Software for system management, data acquisition and processing</li>
</ul>
<p>The system is equipped with a touch-screen operator panel, where the ELSE NUCLEAR software is installed.</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>The software displays in real time the measurement, controls the system status, and allows to set the operative parameters (including the alarm thresholds), to manage the measurement steps. The system provides I/O contacts for:</p>
<ul>
<li>Good functioning status</li>
<li>Alarm status</li>
<li>Pump activation input from customer PLC</li>
<li>Available I/O contact for specific requirements</li>
</ul>
<p>The software is equipped with a routine for quality control, to be used with the test source optionally provided with the system.</p>
<p>The system displays the specific and the total activity, or the count rate and integrated counts.</p>

		</div>
	</div>
</div></div></div></div>
<p>The post <a href="https://www.sciwise.ca/product/lem/">Lem- Liquid Effluent Monitoring System</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
