<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Emergency Response Archives - SciWise Solutions Inc.</title>
	<atom:link href="https://www.sciwise.ca/product-category/emergency-response/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.sciwise.ca/product-category/emergency-response/</link>
	<description></description>
	<lastBuildDate>Thu, 22 Oct 2026 17:02:05 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5.13</generator>

<image>
	<url>https://www.sciwise.ca/wp-content/uploads/2021/08/cropped-logo-new-32x32.png</url>
	<title>Emergency Response Archives - SciWise Solutions Inc.</title>
	<link>https://www.sciwise.ca/product-category/emergency-response/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>FOOMON &#8211; Fully Integrated Food Monitor For Emergency Use</title>
		<link>https://www.sciwise.ca/product/foomon-fully-integrated-food-monitor-for-emergency-use/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 20:48:26 +0000</pubDate>
				<guid isPermaLink="false">https://www.sciwise.ca/?post_type=product&#038;p=7428</guid>

					<description><![CDATA[<p><strong>FOOMON</strong> is a portable fully-integrated instrument specifically conceived for screening of I-131, Cs-134 and Cs-137 accumulated in food samples. Its “on-the-field” design allows deploying the device in any kind of situation, such as routine campaigns or emergency procedures.</p>
<p>The whole device is self-contained in a portable high-IP-grade technical case, for an overall weight < 25 kg. The food samples are to be placed in 500 ml Marinelli beakers, which then are lodged inside a 1 cm thick lead shielding well upon the detector’s end cap. The complete setup and deployment of the system requires less than 5 minutes.
</p>
<p>The post <a href="https://www.sciwise.ca/product/foomon-fully-integrated-food-monitor-for-emergency-use/">FOOMON &#8211; Fully Integrated Food Monitor For Emergency Use</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>FOOMON</strong> is a portable fully-integrated instrument specifically conceived for screening of I-131, Cs-134 and Cs-137 accumulated in food samples. Its “on-the-field” design allows deploying the device in any kind of situation, such as routine campaigns or emergency procedures.</p>
<p>The whole device is self-contained in a portable high-IP-grade technical case, for an overall weight &lt; 25 kg. The food samples are to be placed in 500 ml Marinelli beakers, which then are lodged inside a 1 cm thick lead shielding well upon the detector’s end cap. The complete setup and deployment of the system requires less than 5 minutes.</p>
<p>The User can manage <strong>FOOMON</strong> through the user-friendly control and analysis software installed on the embedded panel PC, automatically calculating the specific activity and the Minimum Detectable Concentration (MDC) of the sample (in Bq/kg). Data are stored locally and can be analysed and downloaded with dedicated software routines.</p>
<p>The measured activity concentration is compared with isotope-specific and food-group-specific alarms. In the case of an alarm, the measurement output is clearly labelled and the alarm status is clearly displayed on the software, which also activates the acoustic alarm.</p>
<p>The counts-to-activity-concentration conversion coefficients are calculated by means of dedicated Monte Carlo calculations.</p>
<p>The MDC achievable in 1 minute, with an average indoor background (150 nSv/h), is as low as about 150 Bq/kg for Cs-137 and Cs-134, and about 90 Bq/kg for I-131. Under the same conditions, MDC as low as about 30 Bq/kg for I-131, and about 40 Bq/kg for Cs-134 and Cs-137, can be achieved in about 10 minutes.</p>
<p>If enabled, the automatic background subtraction subroutine allows further lowering MDC and measurement uncertainty without increasing the counting time.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1628074242289"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h2 class="Product-h2-bdr-title">Additional information</h2>

		</div>
	</div>
<div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-left vc_tta-controls-align-left "><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list"><li class="vc_tta-tab vc_active" data-vc-tab><a href="#1628097896968-560d85d0-d104" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Technical Specifications</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098402201-072240d2-e2cf" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">System Performances</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098476438-07daedc5-6add" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Options</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1792616389071-eadaaeb7-5d63" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Accessories Available Upon Request</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1628097896968-560d85d0-d104" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628097896968-560d85d0-d104" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Specifications</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>Detector probe</strong></p>
<ul>
<li><strong>NaI(Tl) dimension:</strong> 2” x 2”</li>
<li><strong>Resolution:</strong> &lt; 7.5% @662 keV</li>
<li><strong>Lead collimator:</strong> 1.5 cm</li>
<li><strong>MCA:</strong> 1024 channels</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098402201-072240d2-e2cf" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098402201-072240d2-e2cf" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">System Performances</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li><strong>Default isotope library:</strong> 131I, 134Cs, 137Cs</li>
<li><strong>Default food groups:</strong> Infant food, Dairy produce, Other food, and Liquid food (*)</li>
<li><strong>MDA:</strong> about 30-50 Bq in 10 min (depending on isotope)</li>
<li><strong>Maximum measurable activity:</strong> about 1 MBq/kg</li>
<li>No source needed for energy and efficiency calibration</li>
</ul>
<p><em>(*) Following the guidelines given in the EURATOM COUNCIL REGULATION 2016/52</em></p>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098476438-07daedc5-6add" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098476438-07daedc5-6add" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Options</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li>Monte Carlo efficiency curves for custom food groups/measurement classes and material types</li>
<li>250 ml or 1000 ml Marinelli beaker measuring chamber</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1792616389071-eadaaeb7-5d63" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1792616389071-eadaaeb7-5d63" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Accessories Available Upon Request</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li>Quality control sources
<ul>
<li>Natural potassium salt</li>
<li>Cs-137 point source, &lt; 10 kBq</li>
</ul>
</li>
<li>Warranty extension from 12 months to 24 months</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div></div></div></div></div>
<p>The post <a href="https://www.sciwise.ca/product/foomon-fully-integrated-food-monitor-for-emergency-use/">FOOMON &#8211; Fully Integrated Food Monitor For Emergency Use</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HERMES GSU &#8211; Mobile Sample Analyser and Gamma Spectrometer</title>
		<link>https://www.sciwise.ca/product/hermes-gsu-mobile-sample-analyser-and-gamma-spectrometer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 21 Oct 2026 18:26:35 +0000</pubDate>
				<guid isPermaLink="false">https://www.sciwise.ca/?post_type=product&#038;p=7424</guid>

					<description><![CDATA[<p><strong>HERMES GSU</strong> is a portable gamma spectrometry system designed for rapid and precise in-field analysis of environmental samples. As part of the <strong>HERMES</strong> product line, it features a rugged, modular, and self-contained design housed in a high IP-rated technical case, ensuring durability and reliability in demanding conditions.</p>
<p>The post <a href="https://www.sciwise.ca/product/hermes-gsu-mobile-sample-analyser-and-gamma-spectrometer/">HERMES GSU &#8211; Mobile Sample Analyser and Gamma Spectrometer</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p><strong>HERMES GSU</strong> is a portable gamma spectrometry system designed for rapid and precise in-field analysis of environmental samples. As part of the <strong>HERMES</strong> product line, it features a rugged, modular, and self-contained design housed in a high IP-rated technical case, ensuring durability and reliability in demanding conditions.</p>
<p><strong>HERMES GSU</strong> quantifies isotope activity concentrations based on a rich built-in, yet fully-editable, isotope library. Its portability and autonomous operation make it ideal for both routine monitoring and emergency response scenarios.</p>
<p>Samples can be directly collected from the field, placed in 500 ml Marinelli beakers, and inserted into the built-in 1 cm lead-shielded well, minimizing background radiation for immediate, on-the-spot, low MDC analysis, and enhancing measurement accuracy and sensitivity. The system automatically calculates activity concentrations, making it a powerful tool for in-situ, laboratory-grade measurements.</p>
<p><strong>HERMES GSU</strong> features advanced routines for gain stabilization, dead time correction, and automatic energy calibration (relying on natural background only, thus not requiring any radioactive reference source). Efficiency calibration curves are generated using validated Monte Carlo simulations. Predefined efficiency curves are available for different sample matrices, including soil, water, and foodstuffs, across various densities. Custom calibration curves can be provided upon request.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1628074242289"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h2 class="Product-h2-bdr-title">Additional information</h2>

		</div>
	</div>
<div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-left vc_tta-controls-align-left "><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list"><li class="vc_tta-tab vc_active" data-vc-tab><a href="#1628097896968-560d85d0-d104" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Technical Specifications</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098402201-072240d2-e2cf" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Additional features</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098476438-07daedc5-6add" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Accessories Available Upon Request</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1628097896968-560d85d0-d104" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628097896968-560d85d0-d104" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Specifications</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li><strong>Dimensions (WxLxH):</strong> 500 × 310 × 460 mm</li>
<li><strong>Weight:</strong> &lt; 20 kg</li>
<li><strong>Protection grade:</strong> IP67 (closed lid) Operating temperature: -20°C ÷ 50 °C</li>
<li><strong>Power:</strong> LiFePo4 batteries</li>
<li><strong>MCA:</strong> up to 2048 channels</li>
<li><strong>Energy range:</strong> 30 keV ÷ 3 MeV</li>
<li><strong>Resolution at 662 keV (Cs-137):</strong> &lt;7.5% (typical)</li>
<li><strong>Minimum Detectable Concentrations (MDC):</strong> see table</li>
<li>Automatic gain stabilization and energy calibration</li>
<li>Isotope library examples:
<ul>
<li><strong>Medical isotopes:</strong> F-18, Tc-99m, Mo-99, Ga-67, I-131, In-111, Sm-153, Tl-201</li>
<li><strong>Naturally Occurring Radioactive Material (NORM):</strong> K-40, Ra-226, U-238, Th-232</li>
<li><strong>Industrial Isotopes:</strong> Mn-54, Co-57, Co-60, Zn-65, Y-88, Ce-139, Ba-133, Cs-137, Eu152, Eu-154, Ho-166m, Ir-192, Lu-176, Cf252</li>
<li><strong>Special Nuclear Materials (SNM):</strong> Na-22, Pu‑239, Am-241</li>
</ul>
</li>
</ul>
<p><strong>Calculated MDC in Bq/kg of the system, at ambient H*(10) rate equal to 100 nSv/h</strong></p>
<table class="pro-detail">
<thead>
<tr>
<th>Isotope</th>
<th>1 Minute<br />
Measurement Time</th>
<th>5 Minutes<br />
Measurement Time</th>
<th>10 Minutes<br />
Measurement Time</th>
</tr>
</thead>
<tbody>
<tr>
<td>I-131</td>
<td>85</td>
<td>40</td>
<td>30</td>
</tr>
<tr>
<td>Cs-137</td>
<td>140</td>
<td>60</td>
<td>45</td>
</tr>
<tr>
<td>Co-60</td>
<td>230</td>
<td>105</td>
<td>75</td>
</tr>
<tr>
<td>Cs-134</td>
<td>160</td>
<td>70</td>
<td>50</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098402201-072240d2-e2cf" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098402201-072240d2-e2cf" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Additional features</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li>GPS/WiFi/Mobile connection module</li>
<li>Accessory case</li>
<li>Marinelli beaker containing natural potassium salt for quick on-site energy calibration</li>
<li>Predefined Monte Carlo efficiency curves for water, soil and food matrices</li>
<li>Built-in, fully-editable isotope library</li>
<li>Multi-threshold alarm management</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098476438-07daedc5-6add" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098476438-07daedc5-6add" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Accessories Available Upon Request</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li>Integrated label printer</li>
<li>Integrated scale</li>
<li>Additional Marinelli beakers</li>
<li>IP65 10” screen rugged tablet (replacing the panel PC)</li>
<li>Custom Monte Carlo efficiency curves for user-provided sample matrices</li>
<li>Photovoltaic panel power supply system</li>
<li>Automatic continuous water sampling system with pump and modified Marinelli</li>
<li>Warranty extension from 12 months to 24 months</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div></div></div></div></div>
<p>The post <a href="https://www.sciwise.ca/product/hermes-gsu-mobile-sample-analyser-and-gamma-spectrometer/">HERMES GSU &#8211; Mobile Sample Analyser and Gamma Spectrometer</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ELSE NUCLEAR AERIS: Field Gamma Spectrometer for Air Filter Analysis</title>
		<link>https://www.sciwise.ca/product/aeris-portable-field-gamma-spectrometer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 14 Sep 2026 19:58:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.sciwise.ca/?post_type=product&#038;p=7374</guid>

					<description><![CDATA[<p>The <strong>ELSE NUCLEAR AERIS</strong> is a rugged, field-ready portable gamma spectrometric system engineered for immediate, in-situ analysis of radioactive contamination on air particulate sampling media. Distributed in Canada by <strong>SciWise</strong>, the AERIS system eliminates sample transport delays to off-site laboratories by providing fast radionuclide identification and activity quantification directly in the field.</p>
<p>The post <a href="https://www.sciwise.ca/product/aeris-portable-field-gamma-spectrometer/">ELSE NUCLEAR AERIS: Field Gamma Spectrometer for Air Filter Analysis</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>The <strong>ELSE NUCLEAR AERIS</strong> is a rugged, field-ready portable gamma spectrometric system engineered for immediate, in-situ analysis of radioactive contamination on air particulate sampling media. Distributed in Canada by <strong>SciWise</strong>, the AERIS system eliminates sample transport delays to off-site laboratories by providing fast radionuclide identification and activity quantification directly in the field.</p>
<p>Deployable in fixed stations or mobile configurations, AERIS directly accepts standard particulate filters and charcoal cartridges up to 60 mm in diameter. Featuring a high-sensitivity scintillation detector enclosed in a lead shield, the instrument delivers lab-grade spectrometric accuracy even in challenging, high-background radiation environments.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1628074242289"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h2 class="Product-h2-bdr-title">Additional information</h2>

		</div>
	</div>
<div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-left vc_tta-controls-align-left "><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list"><li class="vc_tta-tab vc_active" data-vc-tab><a href="#1628097896968-560d85d0-d104" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Key Features &amp; Benefits</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098402201-072240d2-e2cf" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Applications</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098476438-07daedc5-6add" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Technical Specifications</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1705340845757-6e12ce0a-8f90" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Minimum Detectable Activity (MDA) Performance</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1789412898982-20b27d71-d53c" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Request a Quote or Technical Demonstration</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1628097896968-560d85d0-d104" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628097896968-560d85d0-d104" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Key Features &amp; Benefits</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li><strong>On-Site In-Situ Analysis:</strong> Perform rapid isotopic identification and activity quantification (Bq/m3) without sending air samples to an external laboratory.</li>
<li><strong>High-Sensitivity Detection:</strong> Powered by a 2&#8243;x2&#8243; NaI (TI) scintillation crystal coupled with Silicon Photomultipliers (SiPM), an integrated digital Multi-Channel Analyzer (MCA), and a 1 cm cylindrical lead shield.</li>
<li><strong>Universal Media Compatibility:</strong> Accommodates particulate filters and TEDA-impregnated charcoal cartridges up to 60 mm diameter, utilizing Monte Carlo-calculated efficiency curves for standard geometries.</li>
<li><strong>Dual Operating Modes:</strong>
<ul>
<li><strong>Guided Field Mode:</strong> One-button start and automated energy calibration designed for non-specialist field operators.</li>
<li><strong>Expert Mode:</strong> Full spectrometric control, custom isotope library configuration, and detailed spectral analysis for health physicists.</li>
</ul>
</li>
<li><strong>Rugged &amp; Portable:</strong> Compact 12 kg chassis with an IP65 ingress rating, an operating temperature envelope of -10°C to +45°C, and a high-impact transport case.</li>
<li><strong>Extended Field Autonomy:</strong> Reversible fast startup (&lt;2 minutes) and internal rechargeable battery providing 3 hours of continuous operation (extendable to 8 hours).</li>
<li><strong>Connected Field Intelligence:</strong> Integrated GNSS/GPS positioning and an industrial cellular router (3G / 4G LTE / 5G NR, Wi-Fi, Ethernet LAN, USB, RS-232) for automatic data transmission to central radiological networks.</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098402201-072240d2-e2cf" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098402201-072240d2-e2cf" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Applications</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li><strong>Nuclear Facility Air Quality &amp; Perimeter Monitoring:</strong> Continuous or routine surveillance of airborne particulate releases.</li>
<li><strong>Emergency Response &amp; First Responder Teams:</strong> Instant isotopic characterization of fallout or plume activity following radiological incidents.</li>
<li><strong>Health Physics &amp; Radiation Protection:</strong> In-plant air sampling verification during maintenance, outages, and decommissioning.</li>
<li><strong>Environmental &amp; Regulatory Compliance:</strong> On-site verification of ambient airborne radionuclides without sample transit latency.</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098476438-07daedc5-6add" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098476438-07daedc5-6add" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Specifications</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<table class="pro-detail">
<thead>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
</thead>
<tbody>
<tr>
<td>Detector Type</td>
<td>2&#8243; × 2&#8243; NaI(Tl) scintillator coupled with SiPM</td>
</tr>
<tr>
<td>Multichannel Analyzer</td>
<td>Integrated Digital MCA</td>
</tr>
<tr>
<td>Energy Resolution</td>
<td>≤ 7% FWHM at 137Cs</td>
</tr>
<tr>
<td>Energy Range</td>
<td>30 keV to 3 MeV</td>
</tr>
<tr>
<td>Dose Rate Range</td>
<td>0.005 to 250 µSv/h (137Cs)</td>
</tr>
<tr>
<td>Shielding</td>
<td>Cylindrical lead shield (1 cm thickness)</td>
</tr>
<tr>
<td>Filter / Cartridge Geometry</td>
<td>Up to 60 mm diameter (glass fiber, paper, charcoal/TEDA cartridges)</td>
</tr>
<tr>
<td>Output Metrics</td>
<td>Activity (Bq), Activity Concentration (Bq/m³), MDA, Ambient Dose Rate (µSv/h)</td>
</tr>
<tr>
<td>Alarms</td>
<td>Visual and acoustic indicators on user-settable thresholds</td>
</tr>
<tr>
<td>Connectivity</td>
<td>3G / 4G LTE / 5G NR, Wi-Fi, LAN, USB, RS-232, GPS/GNSS</td>
</tr>
<tr>
<td>User Interface</td>
<td>Dual input: Sunlight-readable touch screen + rugged trackball</td>
</tr>
<tr>
<td>Ingress Protection</td>
<td>IP65 certified</td>
</tr>
<tr>
<td>Dimensions &amp; Weight</td>
<td>40 × 30 × 20 cm; 12 kg (excluding transport case)</td>
</tr>
<tr>
<td>Operating Temperature</td>
<td>-10°C to +45°C</td>
</tr>
<tr>
<td>Battery Life</td>
<td>3 hours standard (extendable up to 8 hours)</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1705340845757-6e12ce0a-8f90" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1705340845757-6e12ce0a-8f90" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Minimum Detectable Activity (MDA) Performance</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>Reference values measured on 1 mm glass fiber filters under 100 nSv/h natural background:</p>
<table class="pro-detail">
<thead>
<tr>
<th>Radionuclide</th>
<th>5-Minute Count</th>
<th>10-Minute Count</th>
<th>40-Minute Count</th>
</tr>
</thead>
<tbody>
<tr>
<td>Iodine-131 (¹³¹I)</td>
<td>7.94 Bq</td>
<td>5.58 Bq</td>
<td>2.76 Bq</td>
</tr>
<tr>
<td>Barium-133 (¹³³Ba)</td>
<td>7.70 Bq</td>
<td>5.40 Bq</td>
<td>2.67 Bq</td>
</tr>
<tr>
<td>Cesium-137 (¹³⁷Cs)</td>
<td>4.92 Bq</td>
<td>3.46 Bq</td>
<td>1.71 Bq</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1789412898982-20b27d71-d53c" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1789412898982-20b27d71-d53c" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Request a Quote or Technical Demonstration</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>SciWise delivers advanced radiation instrumentation, calibration, and support services. Contact our technical applications team today to review efficiency calibrations for your specific filter cartridges or request a quote for the ELSE NUCLEAR AERIS system.</p>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
<p>The post <a href="https://www.sciwise.ca/product/aeris-portable-field-gamma-spectrometer/">ELSE NUCLEAR AERIS: Field Gamma Spectrometer for Air Filter Analysis</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ELSE Nuclear THYMON: Portable Thyroid Monitor for Emergency Use</title>
		<link>https://www.sciwise.ca/product/else-nuclear-thymon-portable-thyroid-monitor/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 14 Sep 2026 19:14:55 +0000</pubDate>
				<guid isPermaLink="false">https://www.sciwise.ca/?post_type=product&#038;p=7365</guid>

					<description><![CDATA[<p>The <strong>ELSE Nuclear THYMON</strong> is a compact, high-sensitivity thyroid monitoring system engineered for rapid, reliable detection of Radioiodine (I-131) contamination during radiological emergencies and population triage.</p>
<p>The post <a href="https://www.sciwise.ca/product/else-nuclear-thymon-portable-thyroid-monitor/">ELSE Nuclear THYMON: Portable Thyroid Monitor for Emergency Use</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>The <strong>ELSE Nuclear THYMON</strong> is a compact, high-sensitivity thyroid monitoring system engineered for rapid, reliable detection of Radioiodine (I-131) contamination during radiological emergencies and population triage.</p>
<p>Combining a collimated NaI(Tl) scintillation detector with advanced silicon photomultiplier (SiPM) readout electronics and an intuitive rugged tablet, THYMON delivers high-accuracy screening in under two minutes without requiring nuclear physics expertise. Fully compliant with IEC 61582 standards, it is suitable for nuclear emergency response teams, first responders, hospital radiation safety officers, and civil defense agencies.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1628074242289"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h2 class="Product-h2-bdr-title">Additional information</h2>

		</div>
	</div>
<div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-left vc_tta-controls-align-left "><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list"><li class="vc_tta-tab vc_active" data-vc-tab><a href="#1628097896968-560d85d0-d104" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Key Advantages for Emergency Response</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098402201-072240d2-e2cf" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">System Architecture</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098476438-07daedc5-6add" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Technical Specifications</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1705340845757-6e12ce0a-8f90" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Optional Modules &amp; Accessories</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1789412898982-20b27d71-d53c" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Request Information from SciWise</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1628097896968-560d85d0-d104" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628097896968-560d85d0-d104" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Key Advantages for Emergency Response</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li><strong>Rapid Triage Screening (2 Minutes):</strong> Achieves typical Minimum Detectable Activities (MDA) between 90 and 120 Bq in 2-minute screening runs, lowering even further with automated background subtraction enabled.</li>
<li><strong>Age-Specific Response Functions:</strong> Features pre-configured response functions validated via physical neck phantoms at CIEMAT for 1 yo, 5 yo, 10 yo, 15 yo, adult female, and adult male demographics. Additional custom age profiles can be defined directly by users.</li>
<li><strong>Zero Calibration Source Needed:</strong> Engineered for immediate deployment; no calibration radioactive source is required for operational energy and efficiency calibration.</li>
<li><strong>Flexible Hands-Free &amp; Handheld Modes:</strong> Comes equipped with an extendable support frame that functions both as a desktop mount and a freestanding floor tripod, minimizing positioning errors ($\le \pm20\%$).</li>
<li><strong>Automated Action Level Logic:</strong> Automatically flags user-configured screening thresholds per age group based on two-tier Action Level criteria for prompt medical referral.</li>
<li><strong>Rugged All-Weather Reliability:</strong> Rated IP67 during transit in its heavy-duty case and IP65 in operational deployment, complete with glove-friendly capacitive touchscreen control.</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098402201-072240d2-e2cf" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098402201-072240d2-e2cf" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">System Architecture</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>The THYMON emergency monitoring system consists of three integrated subcomponents:</p>
<ol>
<li><strong>High-Precision Detector Probe:</strong> Houses a 1.5&#8243;x1.5&#8243; NaI(Tl) crystal shielded by a 1.5 cm lead collimator and coupled to a SiPM matrix with integrated Multi-Channel Analyzer (MCA) readout electronics.</li>
<li><strong>Extendable Support Structure:</strong> A multi-configuration tripod and table-top mount that ensures repeatable positioning against the thyroid to eliminate operator alignment variance.</li>
<li><strong>Ruggedized Control Tablet:</strong> An IP65-rated touchscreen unit running automated measurement algorithms, data logging, archive review, and export routines.</li>
</ol>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098476438-07daedc5-6add" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098476438-07daedc5-6add" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Specifications</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<table class="pro-detail">
<thead>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
</thead>
<tbody>
<tr>
<td>Detector Type</td>
<td>1.5&#8243; × 1.5&#8243; NaI(Tl) scintillation crystal</td>
</tr>
<tr>
<td>Readout Electronics</td>
<td>SiPM-coupled compact Multi-Channel Analyzer (MCA)</td>
</tr>
<tr>
<td>Shielding / Collimation</td>
<td>1.5 cm lead collimator</td>
</tr>
<tr>
<td>Target Radionuclide</td>
<td>Iodine-131 (I-131)</td>
</tr>
<tr>
<td>Minimum Detectable Activity (MDA)</td>
<td>Typically 90 – 120 Bq (in 2-minute count)</td>
</tr>
<tr>
<td>Maximum Measurable Activity</td>
<td>&gt; 3 MBq</td>
</tr>
<tr>
<td>Measurement Uncertainty</td>
<td>≤ ±20% (positioning uncertainty)</td>
</tr>
<tr>
<td>Target Age Groups</td>
<td>1 yo, 5 yo, 10 yo, 15 yo, Adult Female, Adult Male, + User Custom</td>
</tr>
<tr>
<td>Compliance Standard</td>
<td>IEC 61582</td>
</tr>
<tr>
<td>Probe Weight</td>
<td>3.5 kg</td>
</tr>
<tr>
<td>Total System Weight (with Case)</td>
<td>~19 kg</td>
</tr>
<tr>
<td>Transport Dimensions</td>
<td>62.8 × 49.2 × 22.3 cm</td>
</tr>
<tr>
<td>Ingress Protection (IP Rating)</td>
<td>IP67 (transport case closed), IP65 (operational setup)</td>
</tr>
<tr>
<td>Operating Temperature</td>
<td>-20°C to +50°C</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1705340845757-6e12ce0a-8f90" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1705340845757-6e12ce0a-8f90" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Optional Modules &amp; Accessories</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li><strong>Committed Effective Dose Calculation:</strong> Automated software calculations following ICRP 119 and ICRP 103 guidelines, enabling dose Action Levels aligned with the Triage, Monitoring, and Treatment (TMT) Handbook.</li>
<li><strong>Monte Carlo Efficiency Modelling:</strong> Custom Monte Carlo efficiency curves for specific facility demographic classes and non-standard geometries.</li>
<li><strong>Periodic Quality Control Source:</strong> Low-activity Cs-137 check source &lt;10 kBq for routine verification.</li>
<li><strong>Extended Service &amp; Warranty:</strong> Extension options up to 24 months.</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1789412898982-20b27d71-d53c" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1789412898982-20b27d71-d53c" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Request Information from SciWise</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>As an experienced Canadian instrumentation provider for health physics, civil protection, and emergency preparedness, SciWise provides complete technical integration, calibration support, and training for the ELSE Nuclear THYMON system.</p>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
<p>The post <a href="https://www.sciwise.ca/product/else-nuclear-thymon-portable-thyroid-monitor/">ELSE Nuclear THYMON: Portable Thyroid Monitor for Emergency Use</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HERMES Rugged Mobile Radiation Survey Units: Beyond Portable Radiation Monitoring</title>
		<link>https://www.sciwise.ca/product/hermes-mobile-radiation-survey-unit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 14 Sep 2026 18:50:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.sciwise.ca/?post_type=product&#038;p=7362</guid>

					<description><![CDATA[<p>FULL-SCALE PERFORMANCE. DEPLOYED WHERE IT MATTERS.</p>
<p>Emergency responders, health physicists, and homeland security teams require radiation detection that delivers laboratory-grade sensitivity directly to the field. The <strong>HERMES Rugged Mobile Radiation Survey Unit</strong> by ELSE NUCLEAR combines modular detector architectures, automated background calibration, and real-time mapping into a single, high-durability system built for rapid on-site deployment.</p>
<p>The post <a href="https://www.sciwise.ca/product/hermes-mobile-radiation-survey-unit/">HERMES Rugged Mobile Radiation Survey Units: Beyond Portable Radiation Monitoring</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>FULL-SCALE PERFORMANCE. DEPLOYED WHERE IT MATTERS.</p>
<p>Emergency responders, health physicists, and homeland security teams require radiation detection that delivers laboratory-grade sensitivity directly to the field. The <strong>HERMES Rugged Mobile Radiation Survey Unit</strong> by ELSE NUCLEAR combines modular detector architectures, automated background calibration, and real-time mapping into a single, high-durability system built for rapid on-site deployment.</p>
<p>Whether configured as a handheld tactical unit or installed as a vehicle-mounted mobile scanning array, HERMES offers unmatched measurement versatility in critical radiation monitoring scenarios.</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid vc_custom_1628074242289"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<h2 class="Product-h2-bdr-title">Additional information</h2>

		</div>
	</div>
<div class="vc_tta-container" data-vc-action="collapse"><div class="vc_general vc_tta vc_tta-tabs vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-spacing-1 vc_tta-tabs-position-left vc_tta-controls-align-left "><div class="vc_tta-tabs-container"><ul class="vc_tta-tabs-list"><li class="vc_tta-tab vc_active" data-vc-tab><a href="#1628097896968-560d85d0-d104" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Key System Advantages</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098402201-072240d2-e2cf" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Versatile Detector Configurations</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1628098476438-07daedc5-6add" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Technical Specifications (HERMES NAI Baseline)</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1705340845757-6e12ce0a-8f90" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Primary Applications</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1789412898982-20b27d71-d53c" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Available Accessories &amp; Options</span></a></li><li class="vc_tta-tab" data-vc-tab><a href="#1789413028417-350c388e-23ff" data-vc-tabs data-vc-container=".vc_tta"><span class="vc_tta-title-text">Deploy High-Performance Radiation Detection with SciWise</span></a></li></ul></div><div class="vc_tta-panels-container"><div class="vc_tta-panels"><div class="vc_tta-panel vc_active" id="1628097896968-560d85d0-d104" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628097896968-560d85d0-d104" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Key System Advantages</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li><strong>Beyond Portable Architecture:</strong> Combines large-volume scintillators and detectors with an ultra-compact system footprint, bridging the gap between fixed portal monitors and field-deployable units.</li>
<li><strong>Rapid Field Deployment:</strong> Built inside an IP67 ruggedized, weatherproof case with custom shock-absorbing foam interior, enabling operation within minutes in ambient temperatures from -20°C to 50°C.</li>
<li><strong>Source-Free Energy Calibration:</strong> Features automated gain stabilization and real-time energy calibration driven entirely by ambient background radiation—eliminating the need to carry radioactive calibration check sources into the field.</li>
<li><strong>Real-Time Mapping &amp; Telemetry:</strong> Integrated GPS, mobile connectivity, Wi-Fi, and LAN allow scan tracks, isotopic identifications, and radiological alarms to be overlaid instantly onto interactive maps and sent to off-site command centers.</li>
<li><strong>Multi-Platform Remote Control:</strong> Operate directly via the built-in touch-screen panel PC or control remotely through a tablet/smartphone app for standoff worker safety.</li>
<li><strong>Extended Autonomous Power:</strong> High-efficiency LiFePO4 battery banks ensure over 8 hours of continuous operation in remote environments.</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098402201-072240d2-e2cf" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098402201-072240d2-e2cf" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Versatile Detector Configurations</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>HERMES is modularly engineered to fit diverse radiological surveillance and survey needs:</p>
<ul>
<li><strong>HERMES NAI / CSI:</strong> Equipped with a 3&#8243;×3&#8243; NaI(Tl) or CsI(Tl) scintillation crystal and Multi-Channel Analyzer (MCA) for isotope identification and gamma spectrometry.</li>
<li><strong>HERMES GMT:</strong> Utilizes Geiger-Müller tubes for broad-range gamma dose rate surveys.</li>
<li><strong>HERMES PLA:</strong> Incorporates large-volume plastic scintillators for high-sensitivity search, interdiction, and contamination control.</li>
<li><strong>HERMES NEU:</strong> Integrated 10B:ZnS neutron detector with a high-density polyethylene moderator for the interdiction of artificial neutron-emitting sources.</li>
<li><strong>HERMES SENTINEL:</strong> A multi-sensor platform combining NaI(Tl), GM counters, and neutron detection for full-spectrum surveillance.</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1628098476438-07daedc5-6add" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1628098476438-07daedc5-6add" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Technical Specifications (HERMES NAI Baseline)</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<table class="pro-detail">
<thead>
<tr>
<th>Parameter</th>
<th>Specification</th>
</tr>
</thead>
<tbody>
<tr>
<td>Detector</td>
<td>3&#8243; × 3&#8243; cylindrical NaI(Tl) with SiPM readout</td>
</tr>
<tr>
<td>Multi-Channel Analyzer (MCA)</td>
<td>Up to 2048 channels</td>
</tr>
<tr>
<td>Gamma Energy Range</td>
<td>30 keV to 3 MeV</td>
</tr>
<tr>
<td>Energy Resolution</td>
<td>&lt; 7.5% typical at 662 keV (137-Cs)</td>
</tr>
<tr>
<td>Dose Rate Measurement Range</td>
<td>0.03 µSv/h to 20 µSv/h</td>
</tr>
<tr>
<td>Ingress Protection</td>
<td>IP67 (lid closed)</td>
</tr>
<tr>
<td>System Weight</td>
<td>&lt; 15 kg (total transport case)</td>
</tr>
<tr>
<td>Dimensions (W × L × H)</td>
<td>410 × 340 × 205 mm</td>
</tr>
<tr>
<td>Battery Life &amp; Power</td>
<td>LiFePO4 battery pack (&gt; 8 hours continuous)</td>
</tr>
<tr>
<td>Connectivity</td>
<td>GPS, 4G/LTE Mobile, Wi-Fi, LAN, Bluetooth</td>
</tr>
<tr>
<td>Operating Temperature</td>
<td>-20°C to +50°C</td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1705340845757-6e12ce0a-8f90" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1705340845757-6e12ce0a-8f90" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Primary Applications</span></a></h4></div><div class="vc_tta-panel-body"><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li><strong>Emergency Response &amp; CBRN Defense:</strong> First responders can sweep affected areas, locate orphan sources, and identify isotopes without delayed laboratory analysis.</li>
<li><strong>Mobile &amp; Vehicle-Mounted Surveys:</strong> Easily retrofitted with a vehicle kit to turn standard patrol trucks or boats into mobile scanning laboratories.</li>
<li><strong>Decommissioning &amp; Environmental Remediation:</strong> Rapid mapping of large outdoor sites, industrial compounds, or soil remediation projects.</li>
<li><strong>Critical Infrastructure &amp; Event Security:</strong> Standoff pedestrian and crowd surveillance at transit hubs, summits, and border crossings.</li>
</ul>

		</div>
	</div>
</div></div></div></div></div></div><div class="vc_tta-panel" id="1789412898982-20b27d71-d53c" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1789412898982-20b27d71-d53c" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Available Accessories &amp; Options</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<ul>
<li>Vehicle mounting bracket with continuous 12V DC power feed</li>
<li>Tactical backpack carrying assembly for dismounted foot surveys</li>
<li>Long-term semi-fixed outdoor installation mounting kit</li>
<li>Supplemental solar / photovoltaic panel recharging kit</li>
<li>Ruggedized external tablet PC</li>
<li>Extended warranty packages (up to 24 months)</li>
</ul>

		</div>
	</div>
</div></div><div class="vc_tta-panel" id="1789413028417-350c388e-23ff" data-vc-content=".vc_tta-panel-body"><div class="vc_tta-panel-heading"><h4 class="vc_tta-panel-title"><a href="#1789413028417-350c388e-23ff" data-vc-accordion data-vc-container=".vc_tta-container"><span class="vc_tta-title-text">Deploy High-Performance Radiation Detection with SciWise</span></a></h4></div><div class="vc_tta-panel-body">
	<div class="wpb_text_column wpb_content_element " >
		<div class="wpb_wrapper">
			<p>SciWise provides end-to-end technical consultation, deployment strategies, and ongoing support for ELSE NUCLEAR instrumentation across Canada. Contact our health physics and instrumentation experts today to request a quote, configure a custom HERMES detector array, or schedule an equipment demonstration.</p>

		</div>
	</div>
</div></div></div></div></div></div></div></div></div></div>
<p>The post <a href="https://www.sciwise.ca/product/hermes-mobile-radiation-survey-unit/">HERMES Rugged Mobile Radiation Survey Units: Beyond Portable Radiation Monitoring</a> appeared first on <a href="https://www.sciwise.ca">SciWise Solutions Inc.</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
